IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123538 Manual Reset Limit Switch is a genuine OEM safety control for the VMSS961005CNAA gas furnace and compatible Goodman/Amana models. This high-limit / rollout switch monitors temperature and opens the circuit if the furnace overheats or experiences flame rollout, shutting down the burners to prevent damage and hazard. As a manual-reset device, it must be physically reset after a trip — a deliberate safety feature that ensures the underlying fault is investigated.
A tripped or failed limit switch is a frequent cause of a furnace that ignites and then shuts off, or that will not fire at all. Replacing a defective switch with the correct OEM part restores reliable overheat and rollout protection.
The genuine Goodman 10123538 is calibrated to the exact trip temperature the furnace was engineered around. Because this is a life-safety control, a generic switch with a different set point can either nuisance-trip or fail to protect the equipment. We strongly recommend OEM for any safety limit.
Moderate (2/5). Requires shutting off power and gas, removing the burner/access panel, disconnecting two spade terminals, and unscrewing the switch from its bracket. Confirm the trip and reset function after install. If you are not comfortable working near the burner assembly, we recommend a licensed HVAC technician.
Match confirmation is available — send your model and serial number to info@nationalhvacparts.com before ordering.