IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 10123529 is an OEM manual-reset high-limit (rollout) switch for Goodman and Amana gas furnaces including the VMS80604BNAA. Unlike an auto-resetting limit, this safety control latches open when it detects an overheat or flame-rollout condition and must be manually reset with the push button — a deliberate design that forces a technician to inspect and correct the root cause (blocked flue, cracked heat exchanger, or airflow fault) before the furnace can fire again.
Because this switch latches on a safety event, the exact trip temperature is critical. The genuine 10123529 carries the factory calibration and correct bracket, while generic substitutes may trip at the wrong point or fail to latch. For a rollout safety device, OEM is strongly recommended — never bypass a tripped switch.
Easy (2/5). Two-wire spade connection with a mounting screw. Shut off power, transfer the wires, and mount in the original position. About 15 minutes. Important: if this switch has tripped, diagnose and fix the cause (airflow, flue, or heat exchanger) before resetting or replacing.