IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 is a genuine OEM manual-reset limit (rollout/high-limit) switch designed for VCES800804BXAA gas furnaces and compatible Goodman/Amana models. This is a critical safety control: it senses excessive temperature at the burner box or heat exchanger and instantly opens the gas circuit to shut the furnace down, protecting against flame rollout and overheating. Because it is a manual reset device, it must be physically reset after tripping — a repeated trip signals an underlying problem (blocked flue, cracked heat exchanger, or airflow restriction) that should be diagnosed before returning the unit to service.
The genuine Goodman OEM switch is calibrated to the exact trip temperature and mounting footprint specified for this furnace. Generic switches with the wrong set point can trip too early (nuisance shutdowns) or, worse, too late — defeating the safety function. On a life-safety control, always install the correct OEM part; do not substitute or bypass.
Easy (2/5). Disconnect power and gas, note the wire positions, unscrew the switch from its bracket, transfer the two terminals, and remount. Common hand tools; 15–20 minutes. Never jumper a tripped limit switch — diagnose the root cause first.