The Goodman 10123533 is a genuine OEM manual reset high-limit switch for the Goodman GMV951155DXAB 96% AFUE variable-speed gas furnace and compatible GMV95 models. This safety control monitors heat exchanger temperature and cuts power to the gas valve if the furnace overheats — for example, from a blocked filter or blower failure — protecting the unit and your home from a fire hazard.
Limit switches are calibrated to a specific trip temperature. The OEM 10123533 matches Goodman's exact set point and mounting footprint, so it protects at the designed threshold. Generic switches with the wrong trip point can nuisance-trip or, worse, fail to open when they should. For a safety device, use the OEM part.
Rated Moderate — involves 120V wiring. Shut off power at the breaker, remove the two spade connectors, unscrew the switch from the heat-exchanger panel, and mount the replacement. If the switch tripped, diagnose the root cause (airflow/blower) before returning the furnace to service.