IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123537 manual reset limit switch (gray) is a genuine OEM safety control for the GMV950905DXBA 95% AFUE gas furnace. This normally-closed thermal switch opens the ignition circuit if it senses excessive heat or a flame rollout, shutting the furnace down until the fault is corrected and the button is manually reset.
The gray body denotes a specific factory trip temperature. Installing a generic switch with the wrong trip point defeats the safety function and can allow dangerous overheating. Always match the exact OEM part for any rollout or limit safety device.
Easy (2/5). Two spade terminals and typically two mounting screws. Disconnect power first, transfer wires one at a time, and investigate why the original tripped before returning the furnace to service.