The Goodman 10123518 is the OEM manual reset high-limit switch for the GMV950453BXA gas furnace and compatible Goodman/Amana models. This temperature-activated safety control opens the ignition circuit if the heat exchanger or blower compartment overheats, shutting the furnace down to prevent damage and fire hazards. It requires a manual reset after tripping, alerting the homeowner to an underlying airflow or overheating problem.
Limit switches are calibrated to a specific trip temperature. The genuine 10123518 carries Goodman's exact rating and mounting geometry, so it protects the furnace at the correct threshold. A generic switch with a different set point can nuisance-trip or, worse, fail to shut the unit down. For a safety control, only the OEM part is appropriate.
Moderate (2/5). A knowledgeable DIYer can replace it in about 20–30 minutes. Cut power to the furnace, note the wire positions, remove the mounting screws, transfer the terminals to the new switch, and remount. If the original tripped, diagnose the airflow or overheating cause before returning the unit to service.