The genuine Goodman 10123517 manual reset limit switch is a direct-fit safety control for the GMH950905CXAC 96% AFUE gas furnace. This high-temperature cutoff opens the control circuit if it senses flame rollout or excessive heat at the burner box, immediately stopping the furnace to protect against fire and heat-exchanger damage. Because it is a manual reset device, it stays open after a trip and requires a physical button press — a deliberate design that forces a technician to inspect the cause before the furnace can run again.
Rollout and manual-reset limits are trip-temperature specific and must match the burner assembly. A mismatched generic switch can nuisance-trip or fail to protect at the correct threshold. This OEM part guarantees the factory trip point, bracket, and terminal layout.
Easy (1/5). Two screws and two spade terminals. Cut power first, and if the switch tripped, diagnose the rollout cause before resetting or replacing.