IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123533 is a genuine OEM manual reset high-limit / rollout safety switch built for the GMH950704CXAB gas furnace. This normally-closed thermal switch opens the control circuit and shuts down ignition if it senses flame rollout or an overheat condition, protecting the heat exchanger and your home. Because it is a manual reset device, tripping requires a deliberate button press to restore operation — a repeated trip signals a real airflow or combustion problem that should be inspected.
Safety switches are trip-point critical. The OEM 10123533 is calibrated to the exact cut-out temperature Goodman engineered for this furnace. Generic replacements with the wrong trip temperature can nuisance-trip or, worse, fail to protect the heat exchanger. For a life-safety component, always fit genuine OEM.
Replacement takes 20–30 minutes. Shut off gas and power, note the wire positions, unclip the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Verify the correct model on your rating plate before ordering — this furnace uses two different limit switches by location. If a switch keeps tripping, have a licensed HVAC technician diagnose the underlying cause.