The Goodman 10123533 manual reset limit switch is a genuine OEM safety control for the GMH950453BXAC 95% AFUE gas furnace. This high-limit switch monitors heat-exchanger and cabinet temperatures and opens the circuit if the furnace overheats — for example from a blocked filter or failed blower. As a manual-reset device, it must be pressed to restore operation, forcing an intentional inspection after a trip rather than silent auto-recycling.
Safety limits must trip at the exact factory temperature. Generic switches with mismatched trip points either nuisance-trip or fail to protect the heat exchanger. This genuine Goodman switch is calibrated to the model's specification for correct, reliable protection.
Easy (1/5). Two spade terminals and two mounting screws. Disconnect power, transfer the wires, and mount the new switch. Identify the root cause of any trip before returning the unit to service.
Always disconnect power before servicing. If the switch trips repeatedly, have the furnace inspected by a licensed technician.