IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123519 Manual Reset Limit Switch is the genuine OEM high-limit / rollout safety switch used on GKS91155DXAD gas furnaces. This normally-closed switch opens and shuts off the burners if it senses excessive temperature — protecting the heat exchanger from overheating due to restricted airflow, a dirty filter, or a failed blower. Because it is a manual reset device, it stays open after a trip and must be reset by hand, alerting you to an underlying fault that needs attention.
Limit switches are calibrated to a specific trip temperature and mounting footprint. The genuine Goodman switch trips at the factory-specified point and bolts directly to the OEM location. A generic switch with the wrong temperature rating either nuisance-trips or — worse — fails to protect the heat exchanger. For a safety component, always use the OEM-matched part.
Easy (2 of 5). Cut power to the furnace, remove the two wire terminals and mounting screws, install the new switch in the same orientation, and reconnect the wiring. About 15 minutes. After installing, press the reset button and, if the switch trips again, diagnose the airflow or blower fault before returning the furnace to service.