The Goodman 10123533 Manual Reset Limit Switch is a genuine OEM safety control for GKS90904CXAB gas furnaces. This normally-closed switch opens to shut off the burners if it senses an overtemperature or flame-rollout condition, and must be manually reset once the fault is cleared — a key protection against overheating and unsafe operation.
Safety switches must trip at the exact temperature rating specified for your furnace. The genuine 10123533 is calibrated to Goodman's factory trip point, so it protects reliably without nuisance trips. Generic switches with a different set point can either fail to protect or shut the furnace down prematurely. Use the OEM part for safety-critical controls.
Easy–Moderate (2/5). Turn off power and gas, disconnect the two spade terminals, unscrew the old switch, and mount the new one. If the switch keeps tripping after replacement, have a technician diagnose the underlying overheating cause.