IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 10123529 is a genuine OEM manual reset limit switch for Goodman GDH80403AXBA gas furnaces. This thermal safety device monitors temperature at the heat exchanger or burner area and opens the control circuit if it detects an overheat or flame-rollout condition, shutting the furnace down to prevent damage and hazard. Unlike an auto-reset limit, the manual reset design requires a technician to press the button and confirm the fault is cleared — a deliberate safety feature. A tripped or failed switch is a common cause of a furnace that won't fire or locks out on ignition.
Genuine Goodman limit switches are calibrated to the exact trip temperature your furnace's safety design requires. Generic switches may carry a different setpoint, either nuisance-tripping or — far worse — failing to open when they should. On a safety component, always use the OEM-specified part.
Easy (2/5) — Shut off power and gas, disconnect the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Reset if needed and verify normal operation. If the switch trips again after replacement, have the underlying overheat cause diagnosed.