Secure Checkout
The Goodman 10123517 is the genuine OEM manual-reset high-limit / rollout safety switch for GCH950703BXAB gas furnaces. This normally-closed thermal cutout opens if the heat exchanger or burner area exceeds its trip temperature, shutting off the furnace to prevent unsafe overheating. Because it is a manual reset, a tripped switch requires the button to be pressed to restore heat — and a switch that trips repeatedly signals an airflow or combustion issue that should be inspected.
This genuine Goodman OEM switch is calibrated to the exact trip and reset temperatures specified for the GCH95 heat exchanger. Generic limit switches with the wrong setpoint can trip prematurely or, worse, fail to protect against a real overheat. The OEM part guarantees correct, safe cutout behavior.
Easy–Moderate (2/5). Disconnect power, note the wire terminals, remove the mounting screws, and transfer the wiring to the new switch. Typical time is 15–20 minutes. If the switch keeps tripping after replacement, have the furnace inspected for restricted airflow or flame rollout.