IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123517 is a genuine OEM manual-reset high-limit switch engineered for the GCH91155DXAA gas furnace and other compatible Goodman/Amana models. This safety component continuously monitors heat-exchanger and burner-compartment temperatures, tripping to cut gas and shut down the furnace if it detects an overheat condition caused by restricted airflow, a dirty filter, or a blower fault. Because it is a manual-reset design, it requires a deliberate button press to restore operation after a trip — a safeguard that forces a technician to investigate the root cause before the furnace runs again.
The OEM 10123517 is calibrated to the exact trip temperature Goodman specifies for this furnace, ensuring the burner shuts down at the correct threshold. Generic substitutes may trip early (nuisance shutdowns) or late (unsafe), and can differ in bracket geometry or terminal spacing. For a safety-critical limit switch, we strongly recommend the genuine OEM part.
Easy (2/5). Replacement typically takes 15–20 minutes: shut off power and gas, remove the two mounting screws, transfer the spade connectors, and mount the new switch. Always diagnose why the switch tripped before returning the unit to service. If you are unsure, have a licensed HVAC technician perform the work.