The Goodman 10123517 is a genuine OEM manual-reset high-limit safety switch for the GCH90704CXAA gas furnace. This thermally activated switch monitors heat exchanger and burner-area temperature and opens the control circuit if an overheat or flame-rollout condition occurs, shutting down the burners to protect against fire and cracked heat exchangers. Because it is a manual reset device, it must be physically reset with the button after tripping — a deliberate design that forces inspection of the underlying cause before the furnace can restart.
Limit switches are a safety-critical component, and trip temperature is not something to guess at. A generic switch with the wrong open/close set point can either nuisance-trip or, worse, fail to trip when needed. The OEM 10123517 is calibrated to Goodman's exact temperature specification for the GCH90704CXAA, ensuring the furnace shuts down at the correct threshold. Always match this part by OEM number.
Moderate (2/5). Shut off power and gas, note the wiring, remove the two spade terminals and mounting screws, install the new 10123517 in the same orientation, and reconnect. If the switch had tripped, diagnose the root cause (blocked flue, failed blower, dirty filter) before returning the furnace to service. When in doubt, use a licensed HVAC technician.
Genuine OEM Goodman safety part. Please verify your model number before ordering.