IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123539 manual reset limit switch is a genuine OEM safety control for the AMVC960403BNAA gas furnace. This normally-closed switch opens and cuts power to the gas valve if it senses excessive temperature — a blocked flue, failed blower, or restricted airflow — and must be manually reset once the fault is cleared, preventing repeated unsafe cycling.
Because this is a safety-critical component, the genuine OEM Goodman switch is calibrated to the exact trip temperature the AMVC960 series requires. Generic switches with the wrong trip point or mounting footprint can either nuisance-trip or, worse, fail to trip when they should. For any high-limit or rollout control, always fit the OEM part.
Moderate (3 of 5). Turn off power and gas, photograph the wiring, remove the two mounting screws and spade terminals, install the new switch in the same orientation, and reconnect the leads. If a limit was tripping, always diagnose and correct the underlying airflow or venting fault before resetting.