IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123537 is a factory OEM manual reset high-limit switch (gray) for the AMVC950905DXAC gas furnace and compatible Goodman/Amana models. This safety control opens the circuit and shuts down the burners if it senses an overheat or flame-rollout condition, protecting the heat exchanger and your home.
Safety limit switches are calibrated to specific trip temperatures. This genuine OEM switch is factory-set to the correct cutout point for your furnace. Generic switches with mismatched ratings can trip prematurely or, worse, fail to trip — never substitute on a safety control.
Easy (2/5). Shut off power and gas, disconnect the two spade terminals, remove the mounting screws, and install the replacement. If a limit repeatedly trips, diagnose the underlying cause (dirty filter, blocked flue, or failing blower) before returning to service.