The Goodman 10123529 is a genuine OEM manual reset high-limit switch for the AMVC81005CNBC gas furnace. This safety control monitors heat exchanger temperature and cuts gas to the burners if the furnace overheats — protecting against restricted airflow, blower failure, or a cracked heat exchanger. Unlike an auto-reset limit, the manual reset requires a technician to press the button, ensuring the underlying fault is diagnosed before the furnace runs again.
Limit switches are calibrated to a specific trip temperature. The genuine Goodman 10123529 is set to the exact factory rating for this furnace, so it protects without nuisance tripping. A generic switch with the wrong setpoint can either trip early (no heat) or trip late (safety risk). For any safety control, always use the OEM part.
Easy to Moderate. Disconnect power, note wiring, unscrew the old switch from the heat exchanger panel, and mount the replacement in the same location. Basic hand tools; 15–30 minutes. Because this is a safety component, confirm the original overheat cause is resolved.