IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Goodman 10123529 Manual Reset Limit Switch is a direct-fit safety replacement for AMVC80805DNCA variable-speed gas furnaces. This normally-closed thermal switch monitors for dangerous overheating or flame rollout and opens the circuit to shut down the furnace if a fault occurs. Because it is manual-reset, it will not automatically re-close — a deliberate safety feature that forces inspection before the furnace can restart.
This factory-original switch is calibrated to the exact trip temperature specified for your furnace's burner compartment. Safety-critical components should never be substituted with unrated generics — an incorrect trip point can allow unsafe operation or cause nuisance shutdowns. The OEM 10123529 guarantees the correct threshold, terminal type, and mounting.
Easy (2/5). Disconnect the two spade terminals, unscrew the switch from the burner box, and mount the replacement in the same orientation. Always shut off gas and power first. If the switch has been tripping, have a technician diagnose the underlying cause (blocked flue, dirty burners, cracked heat exchanger) before returning the unit to service.
Genuine OEM safety component for Goodman and Amana AMVC80805DNCA furnaces.