The Goodman 10123529 is a genuine OEM manual reset limit switch for the Amana/Goodman AMVC80805CXBA 80% AFUE two-stage variable-speed gas furnace. This safety control opens to shut down the burners if it senses an over-temperature or flame-rollout condition, protecting the heat exchanger and cabinet. Because it is a manual reset device, it stays open until pressed, ensuring the fault is inspected before the furnace restarts.
The genuine Goodman 10123529 is calibrated to the exact trip temperature specified for this furnace and uses the correct terminal spacing and bracket. Generic or "close-enough" switches may trip early (nuisance shutdowns) or late (a real safety risk). As a listed safety component, OEM is strongly recommended.
Shut off power, disconnect the two wire leads, remove the mounting screws, and install the new switch in the same orientation — typically 15–20 minutes. If the old switch tripped, diagnose the root cause (dirty filter, blocked venting, failed blower) before returning the furnace to service.