The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM safety control for the Amana/Goodman AMVC800805CXAB 80% AFUE two-stage furnace. Unlike auto-resetting limits, this normally-closed switch latches open on a flame-rollout or over-temperature event and must be manually reset — a deliberate design that forces a technician to diagnose the root cause (blocked flue, cracked heat exchanger, or failed inducer) before the furnace can run again.
As a UL-listed safety device, the OEM 10123529 guarantees the exact trip temperature and reset behavior the furnace was certified with. Generic substitutes may trip at the wrong threshold or use auto-reset, defeating the safety intent. Always use OEM for rollout protection.
Easy (2/5). Disconnect power, unplug the spade terminals, remove the mounting screws, and install the replacement in the same location/orientation. About 15 minutes. If the switch tripped, diagnose and clear the underlying fault before resetting.