The Goodman 10123519 Manual Reset Limit Switch is a genuine OEM safety control engineered for the Amana/Goodman AMH951155DXAE gas furnace and compatible 96% AFUE models. This normally-closed thermal switch opens the ignition circuit when it detects an over-temperature or flame-rollout condition, shutting down the burners to protect the heat exchanger and cabinet. Because it is a manual-reset device, it must be physically reset after a fault — a deliberate safety feature that flags a problem needing inspection.
The OEM version guarantees exact trip temperature, terminal spacing, and bracket geometry for a drop-in fit. Our generic equivalent meets the same electrical and thermal ratings at a lower price point — ideal for budget-conscious repairs. Both are UL-recognized safety components.
A basic two-wire swap. Disconnect power at the furnace, note wire positions, remove the two mounting screws, transfer the connectors, and reset. Typically a 10–15 minute job for a technician; handy homeowners can complete it, but repeated tripping should be diagnosed by a licensed HVAC professional.