The Goodman 10123533 is a genuine OEM manual reset high-limit safety switch for the AMH950704CXAB gas furnace. This normally-closed thermal switch opens the control circuit and shuts the furnace down if it detects an overheat or flame-rollout condition, protecting the heat exchanger and your home. Because it is manual reset, it stays open after a fault until a technician presses the button — a deliberate safety design that flags a problem instead of silently cycling.
The OEM 10123533 is factory-calibrated to the exact trip temperature the AMH950704CXAB requires. A generic limit switch with a mismatched setpoint may nuisance-trip on normal operation or, worse, fail to trip when it should — a safety risk. For a control this critical, we strongly recommend the genuine part with the correct temperature rating.
Moderate (2/5). Shut off power and gas. Remove the two mounting screws, transfer the spade connectors, and mount the new switch flush against the exchanger surface. Roughly 15–20 minutes. If the switch tripped, diagnose the root cause (blocked flue, dirty filter, bad blower) before returning the furnace to service.