The Goodman 10123533 Manual Reset Limit Switch is a genuine OEM high-temperature safety cutout for the AMH950453BXAB 95% AFUE gas furnace. This normally-closed thermal switch opens and cuts power to the gas valve if it senses an overheat or flame-rollout condition, then stays open until manually reset by pressing the button — a deliberate design that forces a technician to investigate the root cause before the furnace can fire again.
Limit switches are calibrated to a specific trip temperature. A generic switch with the wrong setpoint either nuisance-trips or, worse, fails to cut off in a genuine overheat. The OEM 10123533 carries the exact factory temperature rating for this model, so it protects the heat exchanger as designed. For any safety-rated component, we strongly recommend OEM.
Easy to Intermediate. Typically a two-wire spade-terminal swap secured by one or two screws. Cut power at the disconnect first, note wire positions, and confirm the switch is seated flat against its mounting surface. A repeatedly tripping limit indicates an airflow or heat-exchanger problem that must be diagnosed — do not simply keep resetting it.