The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM safety control for AMH81405DXCB furnaces. This high-limit / rollout switch opens the circuit to the gas valve when it senses excessive temperature — a symptom of flame rollout, a blocked flue, or a failed blower. Because it is a manual reset device, it must be pressed to re-close after a trip, ensuring the furnace does not silently cycle on a genuine safety fault.
Limit switches are calibrated to a specific trip temperature matched to the heat exchanger. Installing a generic switch with the wrong setpoint defeats the safety design — either nuisance-tripping or, worse, failing to trip when it should. Always use the OEM-rated switch for this safety-critical component.
Easy (2/5). Disconnect power, unplug the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Then investigate and correct the root cause (rollout, dirty burners, restricted airflow) before returning the furnace to service.