IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The OEM Goodman 10123529 Manual Reset Limit Switch is a flame-rollout safety control for the AMH80904BXCA gas furnace and compatible Goodman/Amana models. Unlike auto-reset limits, this manual-reset switch latches open when it detects flame rollout or dangerous overheating at the burner box — a deliberate design that forces a physical inspection before the furnace can restart, ensuring an unsafe condition is never silently reset.
A rollout switch is a life-safety device — its trip point and latching behavior must match factory specification exactly. This genuine Goodman part guarantees the correct calibration, bracket, and terminal layout for a true drop-in fit. Generic alternatives may reset too easily or trip inconsistently, defeating the safety function.
Rated Easy to Moderate. With power and gas off, remove the mounting screws, transfer the two spade terminals, and install the replacement. Important: if the old switch had tripped, diagnose and correct the underlying cause (blocked flue, cracked heat exchanger, or dirty burners) before restoring heat. If flame rollout is suspected, have a licensed HVAC technician inspect the unit.