IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 is a genuine OEM manual reset high-limit switch for the AMH80804BXBC gas furnace. This safety control senses temperature at the burner box or heat exchanger and cuts power to the gas valve if the furnace overheats or a flame rollout occurs — protecting against fire and heat-exchanger damage. Unlike an auto-reset limit, the manual reset version must be pressed to restore operation after a trip, which flags that a real fault occurred and was cleared. A tripped or failed switch is a common cause of a furnace that produces no heat.
The genuine OEM 10123529 is calibrated to the exact trip temperature and mounting footprint specified for the AMH80804BXBC. Because this is a life-safety component, an incorrect generic switch with the wrong setpoint can either nuisance-trip or, worse, fail to open during a real overheat. Never substitute an off-spec limit on a safety circuit — use the OEM part.
Rating: Easy to Moderate. Turn off gas and power, disconnect the two spade terminals, unscrew the switch, and mount the replacement in the same orientation. Do not bypass a repeatedly tripping limit — diagnose the overheat cause first.
Fit verified for your model. In stock and ready to ship.