IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM safety control engineered for the Goodman/Amana AMH80803BXBC 80,000 BTU gas furnace. This normally-closed thermal limit opens the control circuit if it senses excessive heat or a flame-rollout condition, shutting down the burners to protect the heat exchanger and your home. Because it is a manual-reset device, it must be physically reset after a fault, alerting the homeowner or technician that a safety event occurred.
Our genuine OEM 10123529 is calibrated to Goodman's exact trip temperature for reliable, code-compliant protection. Aftermarket limits may trip early (nuisance lockouts) or late (a genuine safety risk), so we recommend OEM for this critical safety component.
Easy (2/5). Two wire terminals and one or two mounting screws. Always shut off electrical and gas power before service. If the switch has tripped, diagnose the underlying cause (blocked flue, cracked heat exchanger, or airflow restriction) before resetting.