The Goodman 10123529 is a genuine OEM manual-reset high-limit switch used as a safety control on the AMH80703AXCC gas furnace and other compatible Goodman and Amana models. This switch opens the control circuit and shuts down the burners if it senses an over-temperature or flame roll-out condition, and — unlike an auto-reset limit — it stays open until an operator presses the reset button, forcing a technician to investigate the fault before the furnace can fire again. That manual latch is a key part of the furnace's layered safety system.
The OEM 10123529 is calibrated to the exact trip temperature and mounting footprint specified for the AMH80703AXCC. Because this is a safety device, an out-of-spec generic that trips too high — or fails to trip — defeats its purpose. Always use the genuine calibrated switch.
Easy (2/5). Cut power, unplug the two spade terminals, remove the mounting screws, and swap in the new switch. Important: a tripped manual-reset limit indicates a real fault (blocked airflow, failed inducer, or a cracked heat exchanger) — diagnose the root cause before returning the furnace to service.