Genuine OEM Goodman 10123529 is a manual-reset high-limit / rollout safety switch for the Amana-Goodman AMH80603AXBC gas furnace. This normally-closed thermal switch opens the control circuit and shuts down the burners if it senses an overheat or flame-rollout condition. Because it's a manual reset, it stays open until a technician presses the button — a deliberate safety design that forces the underlying fault to be investigated.
A tripped or failed limit switch will prevent the furnace from firing (no heat) or cause it to short-cycle on limit. Replacing a bad switch with the correct factory-spec part restores safe operation at the proper trip temperature.
OEM Goodman switches are calibrated to the exact trip temperature and mounting footprint your furnace was engineered for. A generic switch with the wrong setpoint can nuisance-trip or, worse, fail to protect the heat exchanger. For a safety-critical control, always use OEM.
Easy (1/5). Cut power, note and transfer the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. A quick job for a tech; DIYers should always diagnose why the switch tripped before resetting.