The Goodman 10123529 is a genuine OEM manual reset limit switch for the AMES921205DNAA gas furnace. This safety control opens the low-voltage circuit and shuts down the burners if it senses an overheat or flame-rollout condition, protecting the heat exchanger and household. Because it is a manual reset device, it must be reset by hand once the fault is cleared — a deliberate design that flags recurring problems.
The OEM 10123529 is calibrated to the exact trip temperature Goodman specifies for this furnace. Generic switches with different trip points can nuisance-trip or, worse, fail to protect the unit. For a safety-critical control like this, we strongly recommend the OEM part.
Moderate (3/5). Shut off power and gas, remove the two mounting screws, transfer the wire terminals, and reinstall. Basic hand tools required. If the switch trips repeatedly after replacement, have a technician diagnose the underlying overheat cause.