The Goodman 10123539 Manual Reset Limit Switch is a genuine OEM high-temperature safety control for the AMEC960603BNAB gas furnace. This switch opens the ignition circuit if it senses abnormal heat — typically from a flame rollout or blocked heat exchanger — and requires a manual reset button press to restore operation, ensuring a technician inspects the furnace before it fires again. If your furnace locks out repeatedly or will not ignite after an overheat event, a tripped or failed limit switch is a leading cause.
The genuine 10123539 is calibrated to the exact trip and reset temperature Goodman engineered for this furnace. Because this is a life-safety device, generic switches with the wrong trip point can nuisance-trip or, worse, fail to protect against a genuine overheat. OEM is strongly recommended for any safety control.
Moderate (2 of 5) — Shut off gas and power, disconnect the two spade terminals, remove the mounting screws, and install the replacement in the same orientation. About 15 minutes for a competent DIYer; professional service recommended if the switch keeps tripping.