The Goodman 10123517 Manual Reset Limit Switch is a genuine OEM high-temperature safety control that shuts off the burners if the furnace overheats. Unlike an auto-reset limit, this manual-reset design will not restart on its own after a trip — a deliberate safety feature that alerts you to a real problem (blocked flue, cracked heat exchanger, or airflow restriction) before the furnace is allowed to fire again. It is a factory-correct replacement for the Amana/Goodman AMEC960603ANAA gas furnace.
Genuine OEM ensures the exact trip temperature and mounting bracket your furnace was engineered around. Generic limit switches may carry a different set point or terminal orientation, which can cause nuisance trips — or worse, fail to protect. On a safety-critical part like this, we recommend OEM.
Easy (2/5). Disconnect power and gas, remove the two mounting screws, transfer the spade terminals, and reinstall. If the switch tripped, diagnose the root cause before pressing reset.