IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123533 is a genuine OEM manual reset high-limit switch for the AKSS920904CXAA gas furnace and compatible Goodman/Amana models. This safety control opens the burner circuit if the furnace exceeds its safe operating temperature, protecting the heat exchanger and cabinet from overheating. Because it is a manual-reset design, it must be pressed to restore operation after a trip — a deliberate feature that flags a genuine overheat event for inspection.
Limit switches are calibrated to a specific trip temperature. The genuine OEM 10123533 is factory-set to Goodman's exact specification, so the furnace's safety response matches the engineered design. Generic switches with the wrong trip point can either nuisance-trip or fail to protect the unit — a safety risk that makes the OEM part the correct choice for this critical control.
Difficulty: Moderate (2/5). Turn off power and gas, note the wiring, unscrew the old switch from its mounting bracket, transfer the terminals to the new 10123533, and remount. Verify the switch sits flush against its mounting surface for accurate temperature sensing. If a limit repeatedly trips, diagnose airflow or heat-exchanger issues before returning to service.
Genuine Goodman OEM safety control. Need fitment help? Email info@nationalhvacparts.com.