The Goodman 10123529 Manual Reset Limit Switch is a genuine OEM safety control engineered as a direct-fit replacement for the Goodman/Amana ADSH800403AXAB gas furnace and many compatible 80% AFUE models. This switch monitors heat-exchanger and burner-area temperature, opening the 24V control circuit to shut down the burners if an unsafe over-temperature or flame-rollout condition is detected. Because it is a manual reset device, it locks out until the cause is corrected and the button is physically pressed — an intentional safety design that flags a recurring problem rather than silently cycling.
The genuine Goodman 10123529 is calibrated to the exact trip temperature specified for your furnace's heat exchanger. Generic substitutes may carry a similar form factor but often differ in set-point or reset behavior, risking nuisance lockouts or — worse — delayed shutdown. For a UL-listed safety component, OEM is the recommended choice.
Replacement is a basic two-wire swap. Shut off power and gas, remove the burner-compartment panel, disconnect the spade terminals, unscrew the old switch, and mount the new one in the same orientation. Most homeowners with basic tools complete this in 15–20 minutes. If the switch trips repeatedly after replacement, have the furnace's airflow and heat exchanger inspected by a licensed technician.