IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 10123529 is a genuine Goodman manual-reset limit switch (rollout / high-limit safety) for the ACVM970603BNBA gas furnace. This normally-closed thermal switch opens the gas-valve circuit if it senses an over-temperature condition — typically caused by flame rollout, a blocked flue, or a failed blower. Because it is manual reset, it stays open after a trip and must be physically reset by pressing the button, alerting the homeowner that a safety event occurred rather than silently cycling.
This is a life-safety component — its calibrated trip temperature must match Goodman's engineering spec exactly. The OEM 10123529 carries the correct factory temperature rating and terminal layout. Generic switches with the wrong set-point can either nuisance-trip or, worse, fail to trip. Always use OEM for safety controls.
Moderate (2/5). Shut off power and gas, photograph the wiring, swap the two spade terminals, and mount with the original screws — about 15–20 minutes. If it trips again after replacement, have a licensed technician diagnose the root cause before operating.