The Goodman 10123529 is a genuine OEM manual reset high-limit switch for the ACES800805CXAA gas furnace. This thermal safety control opens the furnace circuit if it senses excessive heat from a blocked filter, failed blower, or restricted airflow — protecting the heat exchanger from overheating and cracking. The manual-reset design requires a deliberate button press to restore the circuit, alerting the homeowner that a fault occurred rather than silently auto-cycling.
OEM vs. Generic: Limit switches are calibrated to a specific trip temperature matched to the furnace's heat-rise rating. The factory 10123529 opens at exactly the spec Goodman designed for this model. A generic switch with the wrong trip point can either nuisance-trip or, worse, fail to protect the heat exchanger. For a safety-critical control, always use OEM.
Install difficulty: Easy (2/5). Shut off power and gas, disconnect the two wire leads, remove the mounting screws, and install the new switch in the same orientation. Allow 20–30 minutes. If the switch tripped, diagnose the airflow or combustion cause before resetting — a repeatedly tripping limit indicates an underlying problem.