IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 10123529 is a genuine Goodman/Amana manual-reset high-limit safety switch for the ACEC800804BXAA gas furnace. This is a critical safety control: it opens the ignition circuit and shuts down the burners if it senses an overheat or flame-rollout condition, protecting the heat exchanger and the home. Unlike an auto-reset limit, the manual-reset button requires a technician to physically reset it after a trip — a deliberate design that flags an underlying problem.
Because the trip temperature must match Goodman's factory specification, the OEM 10123529 is the only recommended replacement. A generic limit with the wrong setpoint can either nuisance-trip or, worse, fail to protect the heat exchanger. For a primary safety device, always use genuine OEM.
Easy to moderate. The switch mounts with two screws and two push-on terminals — about 15–20 minutes. Disconnect power and gas before servicing. Important: if a limit switch has tripped, diagnose the root cause (blocked airflow, dirty filter, failed blower) before returning the furnace to service.