The Goodman 20162906 is a genuine OEM M4 primary limit switch for Goodman and Amana gas furnaces, including the ACEC960403BNAA. Mounted on the heat exchanger or near the supply plenum, this primary high-limit control continuously monitors supply-air temperature. If airflow is restricted (dirty filter, blower failure, closed registers) and temperatures climb past the rated setpoint, the switch opens to shut off the gas valve and prevent heat exchanger overheating.
The M4 limit is factory-calibrated to a specific trip temperature and mounting bracket profile. This OEM switch guarantees the correct setpoint and fitment. Generic substitutes risk nuisance lockouts or improper protection. For a primary safety device, OEM is strongly recommended.
Easy (1/5) — Two spade terminals and two screws. Disconnect power and gas before servicing. If the limit trips repeatedly, diagnose airflow (filter, blower, ductwork) before assuming the switch has failed.