IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162906 is a genuine OEM M4 primary high-limit switch built for the AMH80905CXCC gas furnace and other compatible Goodman and Amana models. Mounted on the heat exchanger bulkhead, this thermal limit continuously monitors supply-air temperature and shuts down the burners if the furnace overheats due to restricted airflow or a failed blower.
The OEM limit switch is factory-set to the exact open/close temperatures matched to this furnace's heat exchanger, preserving proper cycling and safety. A generic replacement can substitute if temperature ratings match, but mismatched trip points cause nuisance shutdowns or unsafe operation. OEM is recommended for this safety part.
Difficulty: Easy (2/5). Turn off power, disconnect the two wire leads, remove the two mounting screws from the heat-exchanger panel, and install the new limit in the same orientation. Roughly a 15-minute repair for a technician.