IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20162906 is a genuine OEM M4 primary high-limit switch for the AMH80703AXCB gas furnace and compatible Goodman/Amana 80% AFUE models. Mounted on the heat-exchanger/plenum, this temperature-sensing safety control opens the gas circuit if supply airflow is lost — from a dirty filter, failed blower, or closed ducts — protecting the heat exchanger from overheating and cracking. The M4 designation identifies the specific trip temperature and disc profile for this cabinet.
Primary limits are calibrated to a precise cut-out temperature. The OEM 20162906 carries the exact M4 rating engineered for the AMH80703 heat exchanger. Generic limits with the wrong set point cause short-cycling on limit or, dangerously, allow overheating. Match the M-code and mounting geometry — do not guess.
Easy (1/5) — Disconnect power, unplug the two spade terminals, remove the two mounting screws, and install the replacement in the same orientation. Correct the airflow issue that caused the trip. About 10 minutes.