IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The B1796630 is a genuine OEM flowrator inlet tube engineered for the Goodman ATUF364216AA air handler. This small-bore copper tube routes liquid refrigerant into the flowrator (fixed-orifice) metering device at the evaporator coil inlet, ensuring correct refrigerant distribution and proper system charge. A cracked, kinked, or corroded inlet tube causes poor cooling, uneven coil feeding, and capacity loss — replacing it with the factory part restores rated performance.
The genuine Goodman tube is sized to the exact inner diameter and bend geometry required for correct refrigerant flow. Generic substitutes may differ in bore or length, altering metering behavior and risking a brazed-joint leak. We recommend OEM for warranty-safe, exact-fit results.
Advanced — requires recovering refrigerant, brazing, evacuation, and recharge. This is an EPA-certified-technician job; it is not a DIY plug-in part.