IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The B1370820 is a genuine OEM Goodman blower-compartment door interlock switch, supplied pre-wired with factory lead harness for the DMS80704BNA gas furnace and compatible Goodman/Amana models. This SPST safety switch cuts power to the furnace whenever the blower access door is removed, protecting technicians and preventing operation with the compartment open. A furnace that is completely dead — no display, no blower, no ignition — is often the result of a failed or stuck door switch.
The genuine OEM assembly arrives with the correct plunger length, connector, and pre-terminated wiring, so it drops in without splicing or guesswork. Generic switches frequently require re-terminating leads and can misalign with the door, leading to intermittent no-heat faults. OEM guarantees correct actuation depth and safe operation.
Easy–Moderate (2/5). Typically 15–25 minutes: disconnect power, note wire routing, unclip the old switch, transfer or plug in the harness, and secure. Confirm the plunger seats against the door when closed. Shut off power at the breaker before servicing.