IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10135604 Relay is a genuine OEM control relay for Goodman and Amana DCC300XXX3V1DDAA package air conditioners. This relay switches power to a load — such as a fan motor, heater, or contactor coil — in response to the control circuit, serving as a key link in the unit's start/run sequence. Symptoms of a failed relay include a unit that won't energize, chattering contacts, or a component that fails to switch on when called.
The OEM 10135604 matches the original coil voltage, contact rating, and footprint, dropping into the existing harness without modification. Generic relays may save a few dollars but can differ in coil voltage or contact ratings — for a control component, matching OEM spec avoids miswiring and premature failure.
Easy–Moderate (2/5). No refrigerant work required. Cut power at the disconnect, label and move the wires one at a time to the new relay's matching terminals, and remount. Verify coil pull-in and contact continuity with a multimeter. Comfortable DIYers can handle this; otherwise consult an HVAC technician.