IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1226207 Suction-Line Accumulator is a genuine OEM component for the WGPH4549AMAB packaged gas/electric air conditioner. Installed in the suction line ahead of the compressor, the accumulator traps liquid refrigerant and oil during off-cycles, defrost, and low-load conditions, then meters it back as vapor. This prevents liquid slugging — one of the leading causes of premature compressor failure. A cracked, clogged, or corroded accumulator should be replaced with the factory part to keep the refrigerant circuit protected.
The OEM Goodman accumulator is sized to the exact internal volume and connection diameters of this system, so refrigerant velocity and oil return stay within design spec. Generic accumulators may be close in size but mismatched volume can reduce compressor protection or cause oil-return problems. For a sealed-system part, OEM is strongly recommended.
Advanced — requires EPA Section 608 certification. Recover the refrigerant, cut/unbraze the old accumulator, braze in the replacement, pull a vacuum, and recharge to nameplate. This is a sealed-system repair best left to a licensed HVAC technician.