Manage combustion condensate reliably on your Goodman GMH951155DXAE 95% AFUE furnace with this genuine OEM condensate drain trap. High-efficiency furnaces extract so much heat that flue gases condense into acidic water, which must drain away cleanly. This factory trap maintains the water seal that blocks flue-gas backflow while routing condensate to the drain, preventing pressure-switch faults, water leaks, and nuisance lockouts common when a trap becomes cracked, clogged, or improperly seated.
The OEM 20171701 matches Goodman's exact port layout, trap depth, and connection sizes, so it seals and drains as engineered. Generic universal traps often require adapters, sit at the wrong height, or hold too little water to maintain a proper seal — leading to intermittent pressure-switch trips that are difficult to chase down. The genuine trap is the drop-in, no-guesswork choice.
Moderate — 20–30 minutes. Power down the furnace, disconnect the condensate and pressure tubing (label each line), remove the old trap, install and prime the new trap with water, and reconnect all lines. Verify the trap is filled and leak-free, then confirm proper drainage and pressure-switch operation on startup. Basic hand tools only.