IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00038 Auxiliary Limit Switch is a genuine OEM safety control engineered as a direct-fit replacement for the AMVC80604BNAA variable-speed furnace and other compatible Goodman/Amana gas furnaces. The light-blue color code identifies its factory-set trip temperature, ensuring the burner circuit shuts down if abnormal heat is detected around the heat exchanger or blower compartment.
This is a genuine OEM Goodman component with the exact trip point your furnace was designed around. Generic universal limits often carry a different open/close temperature, which can cause nuisance trips or fail to protect the heat exchanger. For a safety device, matching the OEM color code is strongly recommended over a substitute.
Easy (2/5). A two-wire push-on connection secured by one or two screws. Always shut off gas and power before servicing. If the furnace repeatedly trips on limit, consult a licensed HVAC technician.