IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00038 is a genuine OEM auxiliary limit switch — identified by its light blue cap for its specific trip temperature — engineered as a direct-fit replacement for the AMSS921205DNAA furnace and related Goodman/Amana models. This secondary limit adds a layer of over-temperature protection, typically guarding the blower compartment or secondary heat exchanger area and cutting the burners if temperatures climb beyond safe limits.
The color-coded cap on this switch corresponds to an exact trip point. Installing the genuine light-blue OEM switch guarantees the correct temperature calibration and mounting fit. Generic or wrong-color substitutes can trip too early (nuisance shutdowns) or too late (inadequate protection). For a color-coded safety limit, match OEM exactly.
Rating: Easy (2/5). Typically 10–15 minutes. Disconnect power at the furnace, photograph the wiring, remove the mounting screws, and install the new light-blue switch in the identical location and orientation. Verify the replacement carries the same color code as the one you removed. Reconnect the spade terminals and restore power. If it trips repeatedly, investigate airflow and blower operation.
De-energize the furnace before servicing. Consult a licensed technician if unsure.