IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00038 is a genuine OEM auxiliary limit switch (identified by its light-blue body) for the AMH81405DXCA gas furnace and compatible Goodman and Amana models. This secondary safety control provides over-temperature protection at a specific location in the furnace cabinet, backing up the primary limit and opening the burner circuit if it senses excessive heat — for example, from a blocked filter or blower failure.
The color-coded body indicates the factory trip temperature for this exact position in the furnace. Substituting a switch with a different set point defeats the layered safety design. As a life-safety component, the genuine OEM auxiliary limit is the correct replacement.
Easy to Moderate — Cut power, disconnect the two spade terminals, remove the mounting screws, and install the new switch in the same orientation. Roughly a 15-minute job for a confident DIYer; when in doubt, use a licensed technician.