IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 0130F00038 is a genuine Goodman/Amana auxiliary limit switch — identified by its light-blue body color code — for the AMEC961004CNAB gas furnace. It serves as a secondary over-temperature safety, typically monitoring the blower compartment or a specific zone of the cabinet in addition to the primary limit. If temperatures in that area exceed the switch's rated setpoint, it opens the control circuit to shut down heating and protect surrounding components. The color code identifies its trip temperature, so matching the exact part is important.
The light-blue OEM 0130F00038 is factory-set to a precise trip temperature. Installing the wrong color or a generic switch can cause nuisance lockouts or fail to protect the furnace. Always match the OEM color code — for this application, choose the genuine part.
Easy to Moderate (2/5). Disconnect power, access the mounting location, note wire orientation, remove the retaining screws, and install the replacement. Confirm the new switch is the same light-blue temperature code before energizing.